Keranjang
Keranjang Anda saat ini kosong.

WIKA PXS4ME-BCBBB-1TAZZZZ-ZZZ

  • Basic Information & Design
    • Versions Available: Options include versions for hazardous areas (Ex ia), offshore, tropical, geothermal, and ammonia applications, as well as for oxygen, oil-, and grease-free environments. It also complies with NACE MR0175/ISO 15156 and NACE MR0103/ISO 17945 standards.

    • Enclosure Material: Stainless steel 316.

    • Design Features: The enclosure is tamper-proof, featuring an access cover plate with a lead seal option and a laser-engraved stainless steel product label.

    • Mounting Options: Direct mounting, stainless steel wall bracket, or a mounting bracket for 2' pipe mounting.

    • Safety Class: Safety class I (IEC 61298-2:2008).

    Contact Versions & Electrical Ratings

    The switches feature hermetically sealed microswitches with a fixed dead band. The DPDT function is achieved using two simultaneously triggering SPDT microswitches.

    tyle='margin-top: 0 !important'>n-top: 0 !important'>n-top: 0 !important'>
    Contact Version Code Contact Type & Material AC Rating (Resistive Load) DC Rating (Resistive Load)
    E 1 x SPDT, silver, hermetically sealed 250 V, 5 A 24 V, 5 A
    J

    1 x SPDT, gold-plated, hermetically sealed

    250 V, 0.5 A

    24 V, 1 A

    L 1 x DPDT, silver, hermetically sealed 250 V, 5 A 24 V, 5 A
    M

    1 x DPDT, gold-plated, hermetically sealed

    250 V, 0.5 A

    24 V, 1 A

    Sensor Elements & Operating Temperatures

    The permissible medium temperature depends on the selected sensor element and sealing:

    tyle='margin-top: 0 !important'>n-top: 0 !important'>n-top: 0 !important'>

    Accuracy Specifications

    • Set Point Repeatability: ≤1% of the end of the setting range.

    Process & Electrical Connections

    • Process Connections (Standard): ANSI/ASME B1.20.1 (1/4 NPT female, 1/2 NPT female via adapter, 1/2 NPT male via adapter) and DIN EN ISO 228 (G 1/4 female via adapter, G 1/2 A male via adapter, G 1/4 A male via adapter).

    • Process Connection Material: Stainless steel 316L (wetted part).

    • Electrical Connection Types: Threaded connection with a silicone-sheathed connection cable (1.5 m, 3 m, or 5 m lengths) or a copper-free, epoxy resin-coated aluminum alloy terminal box.

    • Wire Cross-Section: 0.5 mm² (20 AWG).

    Operating Conditions & Physical Characteristics

    • Ambient Temperature Range (Ex Version): -30...+60°C (for T6/T85°C) and -30...+85°C (for T4/T135°C).

    • Ingress Protection: IP66 per EN/IEC 60529 (NEMA 4X).

    • Weight: 0.6 kg (with cable outlet and 1.5 m cable) or 1.1 kg (with terminal box).


  • Sensor Element Description Wetted Parts (Element / Sealing) Permissible Medium Temp.
    M Welded diaphragm with antagonist spring Hastelloy C276 / None -40...+200°C
    M

    Diaphragm with antagonist spring and O-ring

    Hastelloy C276 / FPM

    -30...+200°C

    G Piston with antagonist spring and welded diaphragm Hastelloy C276 / FPM -40...+140°C
    P

    Piston with antagonist spring

    Stainless steel 316L / NBR

    -10...+110°C

    P Piston with antagonist spring Stainless steel 316L / EPDM -40...+110°C