{"product_id":"214crtsmb1d3m0450sle5","title":"Rosemount 214C RTD Temperature Sensor","description":"\u003ch1\u003eRosemount 214C RTD Temperature Sensor\u003c\/h1\u003e\n\u003ch5\u003e\u003c\/h5\u003e\n\u003cp\u003eThe Rosemount 214C RTD Temperature Sensor is a Pt-100, single or dual element resistant temperature detector (RTD) that covers a wide range of temperatures, from -321 to 1112°F (-196 to 600°C). An exceptional solution, this sensor has a thin-film and wire-wound design for application flexibility. With many calibration options, including Class A or B sensor accuracy, this sensor also offers Callendar-Van Dusen constants for transmitter-sensor matching to provide the highest level of accuracy.\u003c\/p\u003e\n\u003cdl class=\"row generic-attr\"\u003e\n\u003cdt class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"col-xs-12 col-sm-8 col-md-9\"\u003eFor wire-wound element, 0.05 °C (0.020) maximum ice-point resistance shift after 1g vibration between 20 and 500 Hz for 150 hours according to IEC 60751:2008\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"row generic-attr\"\u003e\n\u003cdt class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\u003cstrong\u003eLead Wires\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"col-xs-12 col-sm-8 col-md-9\"\u003e24 AWG wire, FEP insulated; color coded per IEC 60751\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"row generic-attr\"\u003e\n\u003cdt class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\u003cstrong\u003eTime Constant \/ Response\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"col-xs-12 col-sm-8 col-md-9\"\u003e10.8 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 60751:2008\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"row generic-attr\"\u003e\n\u003cdt class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\u003cstrong\u003eStability\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"col-xs-12 col-sm-8 col-md-9\"\u003e±0.15 °C (0.059 ) maximum ice-point resistance shift following 1,000 hours at maximum specified temperature when measured per methods defined in IEC 60751:2008\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"row generic-attr\"\u003e\n\u003cdt class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"col-xs-12 col-sm-8 col-md-9\"\u003e1000 MΩ minimum insulation resistance when measured at 500 VDC at room temperature\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"row generic-attr\"\u003e\n\u003cdt class=\"col-xs-12 col-sm-4 col-md-3\"\u003e\u003cstrong\u003eCalibration Options\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"col-xs-12 col-sm-8 col-md-9\"\u003eIEC 751 Class A or B; Single point calibration; Calibration schedule or customer-specified calibration range, both with Callendar-Van Dusen constant\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c!----\u003e","brand":"APSS Store","offers":[{"title":"Default Title","offer_id":50389474279727,"sku":"APSS-ITEM-00002683","price":0.0,"currency_code":"IDR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/5826\/9231\/files\/unnamed.jpg?v=1751347031","url":"https:\/\/estore.apss-id.com\/products\/214crtsmb1d3m0450sle5","provider":"APSS Store","version":"1.0","type":"link"}