{"product_id":"calc-007","title":"CALC-007","description":"\u003ch1 class=\"product-title product_title entry-title\"\u003eGas level indicator Portasteele® CALCULATOR (CALC-007)\u003c\/h1\u003e\n\u003cp\u003e\u003cspan class=\"NormalTextRun SCXW142541018 BCX0\"\u003eThe \u003c\/span\u003e\u003cspan class=\"NormalTextRun SpellingErrorV2 SCXW142541018 BCX0\"\u003ePortasteele\u003c\/span\u003e\u003cspan class=\"NormalTextRun SCXW142541018 BCX0\"\u003e® CALCULATOR is the perfect partner to any of\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"NormalTextRun SpellingErrorV2 SCXW142541018 BCX0\"\u003eColtraco\u003c\/span\u003e\u003cspan class=\"NormalTextRun SCXW142541018 BCX0\"\u003e Ultrasonics’ liquid level detectors. It allows you to convert your measured liquid level to an agent weight, precisely and accurately. These readings can then be saved and exported for future reference and traceability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan data-contrast=\"auto\"\u003eSmart data recording\u003c\/span\u003e\u003c\/b\u003e\u003cspan data-ccp-props='{\"335551550\":6,\"335551620\":6,\"335559740\":259}'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-contrast=\"auto\"\u003eThe Portasteele®\u003cspan\u003e \u003c\/span\u003e\u003cspan data-contrast=\"auto\" lang=\"EN-GB\" class=\"TextRun SCXW142541018 BCX0\"\u003e\u003cspan class=\"NormalTextRun SCXW142541018 BCX0\"\u003eCALCULATOR\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis designed for use with cylinders containing liquified agents, where there are distinct liquid and gas regions in the cylinder. However, there are a number of agents, such as CO\u003c\/span\u003e\u003cspan data-contrast=\"auto\"\u003e2 \u003c\/span\u003e\u003cspan data-contrast=\"auto\"\u003eand FE-13, which have what is known as their “critical point” within standard atmospheric temperatures, when stored at pressure. When a substance reaches its critical point, it ceases to exist as distinct layers of liquid and gas and becomes something known instead as a “supercritical fluid”. When this occurs, it is no longer possible to use the liquid level to monitor contents, as there will be no liquid level. \u003c\/span\u003e\u003cspan data-ccp-props='{\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":259}'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-contrast=\"auto\"\u003eThe Portasteele®\u003cspan\u003e \u003c\/span\u003e\u003cspan data-contrast=\"auto\" lang=\"EN-GB\" class=\"TextRun SCXW142541018 BCX0\"\u003e\u003cspan class=\"NormalTextRun SCXW142541018 BCX0\"\u003eCALCULATOR\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003etakes away the option to record data for substances that will likely be in this state. For CO\u003c\/span\u003e\u003cspan data-contrast=\"auto\"\u003e2\u003c\/span\u003e\u003cspan data-contrast=\"auto\"\u003e, for instance, this critical point occurs at 31°C, so if a user inputs a temperature in excess of this, the Portasteele®\u003cspan\u003e \u003c\/span\u003e\u003cspan data-contrast=\"auto\" lang=\"EN-GB\" class=\"TextRun SCXW142541018 BCX0\"\u003e\u003cspan class=\"NormalTextRun SCXW142541018 BCX0\"\u003eCALCULATOR\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewill present an error and they will not be able to proceed and save this measurement. \u003c\/span\u003e\u003cspan data-ccp-props='{\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":259}'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-ccp-props='{\"335551550\":6,\"335551620\":6,\"335559739\":160,\"335559740\":259}'\u003eProduct Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"jet-listing-dynamic-repeater__item\"\u003e\u003cspan\u003ePortasteele® CALCULATOR: Handheld, rechargeable 7-inch touchscreen preloaded with the Portasteele® CALCULATOR applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"jet-listing-dynamic-repeater__item\"\u003e\u003cspan\u003eUSB Type-C to USB Type-A Adapter: To allow direct plug-in of a USB stick for exporting data\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"jet-listing-dynamic-repeater__item\"\u003e\u003cspan\u003eUSB Type-C cable: For charging and data transfer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"jet-listing-dynamic-repeater__item\"\u003e\u003cspan\u003ePower Adapter: For charging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"jet-listing-dynamic-repeater__item\"\u003e\u003cspan\u003eUSB Stick: To save your data on\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"jet-listing-dynamic-repeater__item\"\u003e\u003cspan\u003eQuick Start Instructions: Contains comprehensive guidance as to how to use the calculator\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"jet-listing-dynamic-repeater__item\"\u003e\u003cspan\u003ePhillips screwdriver #1-point size: To remove backplate for sim card (not necessary)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 216mm\u003c\/li\u003e\n\u003cli\u003eWidth: 136mm\u003c\/li\u003e\n\u003cli\u003eDepth: 19mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"APSS Store","offers":[{"title":"Default Title","offer_id":50923007639855,"sku":null,"price":0.0,"currency_code":"IDR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/5826\/9231\/files\/CALC-007.png?v=1751341738","url":"https:\/\/estore.apss-id.com\/products\/calc-007","provider":"APSS Store","version":"1.0","type":"link"}