Cart
Your cart is currently empty.

Secure Payment Gateway

american expressgoogle payjcbmastervisa

Rosemount 8800 Reducer Vort...

Rosemount 8800 Reducer Vortex Flow Meter – 1" (DN25)

Model: 8800DR010SA3E7D1I8A75HR7Q5Q8Q66Q70Q77

  • Flanged vortex flow meter with reducing flanges integrated into the design
  • Reduces cost by eliminating the need for field assembly of reduced piping
  • Both reducer and standard vortex have a common face-to-face dimension which
  • Available with 1 inch through 14 inch (25 mm through 350 mm) line sizes

Key Features

  • Integrated Reducer Design (Built-In, Not Bolted-On)
    Accurately measures lower flow rates without needing separate reducers or pipe modifications
  • Extended Low-Flow Measurement Range
    The reducer design can double the measurable low-end flow range, making it ideal for variable or low-load processes
  • Lower Installation Cost & Risk
    Eliminates field welding and piping adjustments → faster installation and fewer errors
  • Same Face-to-Face Dimensions as Standard 8800
    Drop-in replacement without changing piping layout—engineers love this part
  • Gasket-Free, Non-Clog Design
    No impulse lines or crevices → reduced leak points and maintenance

Specifications

General

  • Series: Rosemount 8800 Reducer Vortex (8800DR)
  • Line Size: 1 inch (DN25)
  • Measurement: Volumetric or mass flow (with multivariable option)

Performance

  • Accuracy:
    • Liquids: ±0.65% of rate
    • Gas/Steam: ±1% of rate
  • Mass Flow (with compensation):
    • Water: ±0.70%
    • Steam: ±2%
  • Turndown Ratio: Up to ~38:1

Operating Conditions

  • Temperature Range:
    • -200°C to +427°C
  • Pressure Capability:
    • Up to high-pressure classes (ANSI 150–1500)

Construction

  • Wetted Materials:
    • 316 / 316L stainless steel
    • Nickel alloys (optional)

Outputs & Communication

  • Signals:
    • 4–20 mA with HART
    • Pulse output
    • FOUNDATION Fieldbus / Modbus options

Request a Quote